Section 15.4: Performance Calculations cont.
Note that is Pd dissipated by the resistor (1 - s)Rr /s so this resistor represents the motor’s gross mechanical load
Subtracting the average (per-phase) mechanical windage and friction losses from the developed power yields the average (per-phase) mechanical output power: